Analog ultrasound systems from the United States detect high_frequency sounds from operating equipment, leaks, and discharges.Converted into audio signals, using a unique heterodyne method, the user can hear these sounds and see them through the headset and the indicator panel of the instrument.It transforms the sound accurately, making it easy for them to recognize and understand. It USES a unique Heterodyning method to convert these signals into audio signals, allowing the user to hear the sound through a headset and see the strength indicator on the pointer.The principle of heterodyne method is like a radio, which can accurately convert the signal into sound, so that people can easily recognize and understand.The advantage of using ultrasonic technology is that it is easy to understand and convenient. Ultrasonic is a high_frequency short_wave signal, which is not directly heard by the human ear. When we can completely detect these sounds through the ultrasonic full-function detector, its characteristics have the following advantages:
1. Ultrasound is directional
2. Ultrasound is easy to block or screen
3.Ultrasonic instruments can be used in noisy environments
4. Changes in ultrasound can predict potential problems
5. The ultrasonic instrument is easy to operate
Application: bearing inspection and lubrication failure monitoring/mechanical fault diagnosis/condensate valve inspection/pressure and vacuum leak detection/leakage amplification fluid application/electrical partial or arc discharge detection/heat exchanger, boiler and condenser/ultrasonic sound test.
Acep m 360 sc: contact auscultation, leak scanning instrument package:
ACEPOM360 pistol with LED bar chart instrument, 8 position sensitivity options, low battery indicator, scan module, rubber focusing probe, stethoscope module, lightweight sponge-lined earphone,9 volt alkaline battery (replaceable), nylon soft pack and integrated instruction manual.
Specification:
Structure: hand-held ABS pistol ultrasonic host, stainless steel sensor housing.
Circuit: SMD/ solid state hybrid heterodyne receiver
Frequency response: 20-100khz (concentrated at 38-42khz)
Indicator: 10-segment LED bar chart (red)
Sensitivity selection: 8 position precision attenuation
Power supply: 9 volt alkaline battery
Low battery voltage display: LED
Earphone: noise-proof, wired monophonic earphone, impedance 16ohms.Noise attenuation exceeding 23dB, meeting or exceeding ANSI specification and OSHA standard.
Other sensors(Option configuration):
Scanning module scm-1 (contactless) : stainless steel Unisonic(single sensor) piezoelectric.
Stethoscope module stm-1 (contact) : insertion type with 5.5' stainless steel waveguide tube.
Rubber focusing probe: collects discrete ultrasonic signals and focuses the detected signals.
Ultrasonic signal generator: patented ultrasonic signal generator.
Response time: 300 ms.
Operating temperature: 32-120℉(0-50℃).
Relative humidity: 10-95% non-condensate up to 86 ° f (30 ° c)
Storage temperature: 0-130℉ (-18-54℃)
Warranty: one year, parts/man hours.(* depending on requirements)
Size: 5.25'X 2' X 8' (332.5px X 125px X 507.5px)
Weight: 11 oz (0.3kg).Carrying bag: soft nylon bag with die-cutting foam.