The units are supplied readytouse straight from the box and filled with a wide range of high performance SKF lubricants. Toolfree activation and timesetting allow easy and accurate adjustment of lubrication flow.
▪Flexible dispense rate from 1 to 12 months
▪Stoppable or adjustable if required
▪Intrinsic safety rating: ATEX approved for zone 0
▪Transparent lubricant container allows visual inspection of dispense rate
▪Compact size, permits installation in restrictive areas
▪Greases and chain oils available
▪SKF DialSet software helps to calculate the correct dispense rate
▪Extensive range of accessories.
Ordering details | |||
Grease | Description | Unit 60 ml | Unit 125 ml |
Multi-purpose | LAGD 60/WA2 | LAGD 125/WA2 | |
LGEM 2 | High loads, | LAGD 60/EM2 | LAGD 125/EM2 |
LGGB 2 | Biodegradable | – | LAGD 125/GB2 |
LGHB 2 | High temperature | LAGD 60/HB2 | LAGD 125/HB2 |
LGHP 2 | High performance | LAGD 60/HP2 | LAGD 125/HP2 |
LGFP 2 | Food processing | – | LAGD 125/FP2 |
LGWM 2 | High load, wide | – | LAGD 125/WM2 |
Chain oil | |||
LHMT 68 | Medium temperature | LAGD 60/HMT68* | LAGD 125/HMT68* |
LHHT 265 | High temperature | – | LAGD 125/HHT26* |
LHFP 150 | Food grade, NSF | – | LAGD 125/HFP15* |
LFFM 80 | Food grade, NSF | – | LAGD 125/FFM80* |
LFFT 220 | Food grade, NSF | – | LAGD 125/FFT22* |
Empty unit suitable | LAGD 60/U* | ||
Empty unit suitable | – | LAGD 125/U* |
Technical data | |
Designation | LAGD 60 and LAGD 125 |
Grease capacity |
|
Nominal emptying time | Adjustable; 1–12 months |
Ambient temperature range | –20 to +60 °C (–5 to +140 °F) |
Maximum operating pressure | 5 bar (75 psi) (at start-up) |
Drive mechanism | Gas cell producing inert gas |
Connection thread | R1/4 |
Maximum feed line length with: |
|
Intrinsically safe approval | II 1 G Ex ia IIC T6 Ga |
EC Type Examination Certificate | Kema 07ATEX0132 X |
Protection class | IP 68 |
Recommended storage temperature | 20 °C (70 °F) |
Storage life of lubricator | 2 years |
Weight | LAGD 125 approx 200 g (7.1 oz) |
Note: For optimum performance, SKF SYSTEM 24 LAGD units filled with LGHP 2 should not be exposed to ambient temperatures over 40 °C (105 °F), or have a time setting longer than 6 months.