NDT ACEPOM630 portable industry X-ray apparatus with good price high performance flaw detector

NDT ACEPOM630 portable industry X-ray apparatus with good price high performance flaw detector

share
  • Detail
  • Parameters

Industrial X-ray flaw detector ACEPOM630 consists of jingjiang amber instrument manufacturing co., LTD. Development and production of X ray testing instrument, it USES a flat image intensifier and built-in high-voltage generator, because the flat image intensifier has the characteristics of rapid response and high sensitivity, so the radiation dose is very low, increase the safety of the operator.

Features:

1. Use no dark room, direct real-time observation without protection;

2. High gain, high sensitivity, high spatial resolution, easy to operate.

3. Lowest radiation dose, safe and reliable, simplified structure, small size, light weight, portable use.

4. Connection to video and computer systems, or video recording systems, on user's request.

Technical Parameter

   1.ACEPOM630 is sealed facility with no water proof;

Spatial resolution   ≥50lp/cm

Grey scale   ≥ level 7

Material thickness ≤ 200mm

Container depth:   600mm

Effective vision : Φ75mm

X Ray tube voltage:    75kV

X Ray tube current:    0.4mA

    Storage environment

   Temperature:   -20℃~55℃;

    Humidity:   ≤95%;

    Atmospheric pressure:   500hPa~1060hPa.

    Work environment

    temperature:   10℃~40℃;

    humidity:   ≤75%;

    Atmospheric pressure:   700 hPa~1060hPa;

    Power supply:   DC 14.4V

     Power :   40VA

Application

It is widely used in manufacturing industry, light metal research, experiment, science and education and scientific instrument.

Safety

The loading voltage of the machine is 75kV and the current is 0.4ma. Under this condition, the range beyond the maximum image receiving plane is 3 0mm, and the maximum allowable specific release kinetic energy of air is 150 microns /h.

A series of strict and careful effective measures have been taken for X-ray leakage, including the lead cover of the X-ray source, the protective lead plate before and after the image intensifier, the lead glass for the fluorescent screen observation window and the collimator device.

This machine is a portable device, and frequent movement may lead to deviation of relative positions between components. Therefore, periodic leakage ray detection should be carried out on this machine to ensure that the leakage ray dose is within the allowable range.Once the leakage radiation exceeds the standard, should immediately stop using, and contact the manufacturer.

Cautions

A. before use, be careful not to hold the button switch in the host when the battery is inserted or connected, otherwise it will cause serious damage to the instrument.

2, the equipment in use, must be put into the aluminum box, if temporarily not used, must be placed horizontally on the table to avoid damage.At ordinary times, aluminum box storage should avoid falling, so as not to damage the instrument;

3. To prolong the service life of the machine, the use of the machine, please avoid continuous boot is too long, is to open a minute stop three minutes, and the current a boot after shutdown, after to a boot, middle must wait at least more than 5 seconds, to avoid the previous high pressure after shutdown after not entirely after the retreat with a high pressure accumulation, flash, breakdown of X-ray tube, man-made machine fault;

4. Keep the set clean and maintained regularly.Use alcohol wring slightly dry after scrubbing, scrubbing do not make water droplets to prevent water infiltration of the machine;

5. At ordinary times should pay attention to don't let the enter button, such as water, alcohol, or the battery plug socket, to prevent circuit fault, which affect use.

6.Pictures if there are any oil traces in the aluminum box during use, it may show that the picture tube has leaked oil (such kind of situation seldom happens), please stop using it immediately and contact the manufacturer or seller immediately.

7.But the machine structure is relatively close, and involves the high pressure, so do not allow users to remove, such as users find such as display is not bright, dark light is not bright, display, and so on and so forth, please stop using immediately and contact the manufacturer, lest cause failure.

8. Special tip: if you use found in the image, a crescent shape defect in general position offset ray part has happened, it could lead to excessive radiation leakage happens, so please stop using immediately, and immediately and contact the manufacturer or distributor, send the instrument back to the manufacturer for repair.

Serious statement

1, when using the machine, large separated protective plate must be installed, the machine's protective design is the screen exists as the design basis, in the absence of a big protective screen, the company does not guarantee that the whole machine can meet the requirements of radiation protection;During operation, the user must operate behind the protective panel, and the operator's hand position should not exceed the range of the extension line of the protective panel's edge. Under this condition, the air specific release kinetic energy rate should not exceed 0.5mGy/h.

2, the machine is a ray product, in general, any involved in the ball tube and image intensifier maintenance to return to the factory, to ensure that after the maintenance of the leakage ray index can meet the safety requirements.If users repair these two items by themselves, the company will not be responsible for the radiation safety of the instrument.

3. The outer packing of the aluminum box of this machine is used for ordinary use. If it is to be shipped, it should be packaged in cartons with foam.

Maintenance

1. The instrument is a precision instrument, do not open the machine casually, in case of accidents. If the instrument does not work properly, only the personnel trained by the company can carry out maintenance, and do not open the box for maintenance by themselves.

2. The instrument should be moisture-proof and heat-proof.

3. Before each use, check whether the collimator of the main engine has obvious Angle deviation and whether the display has broken glass.Every two years, the instrument must be sent back to the factory once, and the factory will carry out a maintenance to ensure safe use.

4. The warranty period of this machine is one year.In order to ensure the safety of use and prevent the damage caused by function failure and aging, the company guarantees that the normal service life of the machine is five years after the factory or six years after the date of product qualification certificate. During this period, the company is responsible for maintenance. After this period, the company will not be responsible for maintenance.

Configuration

1. X ray tube;

2. collimator;

3. Lead block;

4. Battery plug;

5. switch;

6. Hood

7. Plate type X-ray image intensifier

8. Ray shield plate;

9. X-ray machine external sign

10. power socket (not take)

11. The power switch

Origin
China
Brand
ACEPOM
Model
ACEPOM630